Experts in Power Supply Module Repair
Precision Zone specializes in the repair services of power supplies. Our highly trained team of engineers and technicians evaluate and inspect every repair job and our superior customer care team helps keep you informed and up to date with your entire repair process so that you know exactly when it will be completed.
All power supply repairs are done on-site in our 72,000 square foot, state of the art repair facility. Once our repair team starts on the job, we use specialized and customized testing fixtures, Huntron trackers, signal generators, oscilloscopes, milli and mega ohm meters, as well as any other necessary tools we have available to assure quality repair work.
We understand that when your machine goes down, so does your business. This is why our number one goal at Precision Zone is to get you up and running as fast as possible while maintaining our high-quality repair and service standards.
Precision Zone Power Supply Repair Benefits
- Free Quotes and Evaluations
We have a thorough evaluation process that utilizes visual, static, and power tests to determine the failure of the product so you get a comprehensive and accurate quote. Everytime.
- 12-Month Warranty
All products are covered by our comprehensive warranty that includes our parts and labor. Warranty terms and conditions are product specific.
- Competitive Pricing
We know that you have many different options to go to for your repairs. However, we pride ourselves in being able to provide you with a more affordable and competitive repair option with out sacrificing the quality of service we provide.
- Flexible Rush Repair Options
To minimize your equipment downtime, we offer mutliple rush repair options. Standard repair time is typically 1-2 weeks. Rush repair options include 3 day, 2 day, next day, and even same day repairs.
Recently Repaired Products
ETU-3MK01Z
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
QX084
is an
Part of machine
manufactured by
Mitsubishi
Discovered issues:
Bad Hybrid IC’s, Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces), Open Resistor(s)
PD25A
is an
Part of machine
manufactured by
Rubycon Co
Discovered issues:
Bad Input Section, Leaky Capacitors (Open, Corroded Traces), Open Resistor(s), Bad Hybrid IC’s
CPS-12N
is an
Part of machine
manufactured by
Yaskawa
CPS-10NB
is an
Part of machine
manufactured by
Yaskawa
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
PD21B
is an
Part of machine
manufactured by
Shindengen
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
MPS30
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 30kW
Unit generation: First generation
PD14C-1
is an
Part of machine
manufactured by
Mitsubishi
Discovered issues:
Bad DC Bus Capacitor(s), Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
21-1216
is an
Part of machine
manufactured by
United Air Specialists,Inc
Discovered issues:
Bad Hybrid IC’s, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
E0451-521-029
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces), Open Resistor(s)
UV105
is an
Part of machine
manufactured by
HEIDENHAIN
Discovered issues:
Bad Output Section
SNP-825A
is an
Part of machine
manufactured by
Skynet Electronic
Discovered issues:
Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces) Description: Skynet Electronic | Part of machine |
PD21
is an
Part of machine
manufactured by
Shindengen
Discovered issues:
Bad DC Bus Capacitor(s), Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
SLPWAED139-2
is an
Part of machine
manufactured by
Hitachi Seiki
Discovered issues:
Bad Fuse, Bad Hybrid IC’s, Bad Input Section, Bad Output Section, Multiple signs of previous repair
A06B-6087-H130
is an
Part of machine
manufactured by
Fanuc
Discovered issues:
Bad Hybrid IC’s, Bad Output Section, Physical Damage
Part Group: A06B
Model: ALPHA POWER SUPPLY MODULE
Description: H130
MPS20
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Leaky Capacitors (Open, Corroded Traces)
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 20kW
Unit generation: First generation
A16B-1212-0100-01
is an
Part of machine
manufactured by
Fanuc
Discovered issues:
Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
OFSX-100T-UF
is an
Part of machine
manufactured by
Switching Power, Inc.
Discovered issues:
Bad DC Bus Capacitor(s), Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
MPS45A
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad Hybrid IC’s, Bad Output Section
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 45kW
Unit generation: Second generation (2004 or later)
MPS60
is an
Part of machine
manufactured by
Okuma
Discovered issues:
Bad DC Bus Capacitor(s), Bad Hybrid IC’s, Bad Input Section, Leaky Capacitors (Open, Corroded Traces)
Type: DC power supply unit
Regeneration method: Power regeneration type
Unit capacity: 60kW
Unit generation: First generation
A16B-1212-0531-02A
is an
Part of machine
manufactured by
Fanuc
Discovered issues:
Bad DC Bus Capacitor(s), Bad Fuse, Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces)
93-32-5557
is an
Part of machine
manufactured by
HAAS
Discovered issues:
Bad DCCT, Bad Regen Section, Non-supported product - Cannot Test
KP400A-90
is an
Part of machine
manufactured by
Cineco
Discovered issues:
Bad Hybrid IC’s, Bad Input Section, Bad Output Section, Leaky Capacitors (Open, Corroded Traces), Open Resistor(s)
HKT50-525-A
is an
Part of machine
manufactured by
Nemic Lambda
Discovered issues:
Bad Hybrid IC’s, Bad Input Section, Leaky Capacitors (Open, Corroded Traces), Open Resistor(s)